| Electrical Data |
Maximum Frequency:
C08: 70.0 GHz
C12: 40.0 GHz
C19: 26.5 GHz
C29: 18.0 GHz
 Impedence: 50 Ω nominal
 Propagation Velocity:
C08: 75% nominal
C12, C19 & C29: 84% nominal
 Time Delay:
C08: 1.35 ns/ft (4.43 ns/m)
C12, C19 & C29: 1.21 ns/ft (3.97 ns/m)
 Shielding Effectiveness:
-100 dB minimum (cable only)
 Dielectric Withstanding Voltage:
C08: 2.5 kV at 60 Hz
C12: 7.0 kV at 60 Hz
C19: 10.0 kV at 60 Hz
C29: 15.0 kV at 60 Hz
 Capacitance:
C08: 27.0 pF/ft (88.6 pF/m)
C12, C19 & C29: 24.4 pF/ft (80.1 pF/m) |
Mechanical Data |
Finished Outer Diameter:
C08: 0.110 in (0.279 cm)
C12: 0.144 in (0.366 cm)
C19: 0.225 in (0.572 cm)
C29: 0.310 in (0.787 cm)
 Static Bend Radius:
C08: 0.50 in (1.300 cm)
C12: 0.75 in (1.905 cm)
C19: 1.25 in (3.175 cm)
C29: 1.75 in (4.445 cm)
 Weight with Standard Jacket/Armor:
C08: 0.01 lbs/ft (0.018 kg/m)
C12: 0.02 lbs/ft (0.028 kg/m)
C19: 0.04 lbs/ft (0.062 kg/m)
C29: 0.09 lbs/ft (0.134 kg/m) |
|
|
| Mechanical Data (cont'd) |
Operating Temp. Range:
-85 to 392° F (-65 to 200° C)
Above 185° F (85° C) use "T" designation |
Cable Construction |
Inner Conductor: Solid Ag-plated Cu
 Dielectric: PTFE Tape
 Outer Conductor:
Ag-plated Cu Strip/Ag-plated Cu Flat Braid
 Standard Finish: FEP
 (a wide variety of other protective finishes and armors available) |
Available Connectors |
C08: 1.85mm
 C12: 1.85mm, 2.4mm, 2.92mm, 3.5mm, SMA, TNC, Type N
 C19: 3.5mm, BNC, SMA, TNC, Type N
 C29: 7-16 DIN, SMA, TNC, Type N
 (maximum frequency dependent on cable; other connectors available) |
Specifications |
| For attenuation data and additional specifications refer to PDF datasheet. |
|