Curve purple

GrooveTube® Low Loss Cables


High Reliability RF Cable Assemblies

This system cable is made with our industry-leading GrooveTube® and is used in any application where low loss and/or phase stability are critical. Uses include phased array radar, electronic warfare radar systems, and high reliability interconnects. MegaPhase's 1 and 2 Series cables are ideal for thermal-VAC and space applications, while the 5 Series is well suited for antenna feed cable and EMC lab test cable applications. Our rugged construction resists torque, pull and crush forces. All GrooveTube® cable assemblies are tested 100% for S-Parameters and each assembly is serialized. Standard test and data includes VSWR and insertion loss. Additional testing options will be quoted upon request.

Electrical Data
Maximum Frequency:
130 & 230: 18.0 GHz
120: 32.0 GHz
220: 26.5 GHz
520: 50.0 GHz
539: 12.4 GHz

Impedence: 50 Ω nominal

Propagation Velocity:
1 & 2 Series: 80% nominal
5 Series: 69% nominal

Time Delay:
120 & 220: 1.27 ns/ft (4.17 ns/m)
130 & 230: 1.21 ns/ft (3.97 ns/m)
5 Series: 1.47 ns/ft (4.82 ns/m)

Shielding Effectiveness:
1 & 2 Series:
-100 dB minimum (cable only)
5 Series: -110 dB minimum (cable only)

Dielectric Withstanding Voltage:
120, 220 & 520: 10 kV at 60 Hz
130, 230 & 539: 15 kV at 60 Hz

Capacitance:
1 & 2 Series: 26.7 pF/ft (87.6 pF/m)
5 Series: 29.0 pF/ft (95.1 pF/m)

Mechanical Data
Finished Outer Diameter:
120, 220 & 520: 0.285 in (0.724 cm)
130 & 230: 0.400 in (1.016 cm)
539: 0.460 in (1.168 cm)

Static Bend Radius:
120, 220 & 520: 0.5 in (1.27 cm)
130 & 230: 1.0 in (2.54 cm)
539: 1.5 in (3.81 cm)

Weight with Standard Jacket/Armor:
120 & 220: 0.04 lbs/ft (0.060 kg/m)
130 & 230: 0.08 lbs/ft (0.119 kg/m)
520: 0.05 lbs/ft (0.067 kg/m)
539: 0.10 lbs/ft (0.149 kg/m)

Crush Resistance:
250 lbs/linear in (44.6 kg/linear cm)
Mechanical Data (cont'd)
Operating Temp. Range:
120 & 220: -67 to 275° F (-55 to 135° C)
130 & 230: -85 to 248° F (-65 to 120° C)
5 Series: -67 to 275° F (-55 to 135° C)
For all series:
Above 185° F (85° C) use "T" designation

Cable Construction
Inner Conductor:
1 & 5 Series: Solid Ag-plated Cu
2 Series: Stranded Ag-plated Cu

Dielectric:
1 & 2 Series: Low Density PTFE
5 Series: PTFE

Outer Conductor: GrooveTube® Cu

Standard Finish:
120 & 220: Polyolefin over Metallic Braid
130, 230 & 5 Series:
Neoprene over Metallic Braid

(a wide variety of other protective finishes and armors available)

Available Connectors
120 & 220: 1.85mm, 2.4mm, 2.92mm, 3.5mm, 7mm, BNC, SMA, TNC, Type N

130 & 230: 3.5mm, 7mm, BNC, SMA, TNC, Type N

520: 1.85mm, 2.4mm, 2.92mm, 3.5mm, 7mm, 7-16 DIN, BNC, SMA, TNC, Type N, ZMA, ZN

539: 7-16 DIN, SMA, TNC, Type N

(maximum frequency dependent on cable; other connectors available)

Specifications
For attenuation data and additional specifications refer to PDF datasheet.


GrooveTube® Low Loss Cables